Quick Link
Quick Contact
Address
No. 99 Xingai Avenue, Liangjiang New Area, Chongqing, China
Tel
+86--18723890577
Our Newsletter
Subscribe to our newsletter for discounts and more.
Robust oil-immersed transformers (30–1600kVA, up to 11.5kV) with vacuum-cast UL V0 epoxy insulation, electrostatic harmonic shielding, and Pt100 smart monitoring. Full-mitred cores ensure durability; configurable 80–660V outputs and certifications suit harsh industrial B2B exports.
200kVA 2000kVA 5000kVA Three Phase Electric Oil Immersed Type Distribution Transformer 6.6kV 11kV 13.8kV to 415v 433v
A full-line supply, offering a wide range of transformers consisting of:
Distribution transformers (5KVA to 5000 KVA/36KV)
Pole transformers (up to 500 KVA/36KV)
Pad-mounted transformers (up to 3000 KVA/36KV)
Amorphous transformers (5KVA to 2000 KVA/36KV)
Superior Harmonic Suppression: Built-in electrostatic shielding between windings isolates stray capacitance and blocks parasitic harmonic interference.
High-Strength Core Crafting: Features a five-step lap-stack core design using grain-oriented silicon steel to minimize excitation current and noise.
Advanced Epoxy Casting Insulation: Coils are cast with premium flame-retardant epoxy resin, achieving a UL V0 rating with zero toxic gas emission during thermal stress.
Robust Short-Circuit Resistance: High-voltage coils use segmented copper foil/conductors, providing exceptional mechanical stability against severe grid faults.
Smart Thermal Regulation: Equipped with independent Pt100 temperature sensors and an automated control interface supporting long-distance signal routing up to 20 meters.

Ambient Temperature Range: Optimized for operation under a maximum ambient temperature of +40°C, with an altitude ceiling of 1000 meters.
Corrosive & Dust Control: Designed for installation in environments completely free from severe dust, explosive hazards, chemical depositions, or corrosive gases.
Grid Waveform Limits: Requires a power supply voltage waveform approximating a standard sine wave, with a maximum phase asymmetry limit of 1%.
Mechanical Stability Zones: Suitable for structural setups experiencing minimal external vibration, with a maximum allowable installation tilt angle of 5%.
|
No. |
Capacity KVA |
Primary voltage KV |
Secondary voltage V |
Frequency Hz |
|
1 |
100 |
12 |
400 |
50 |
|
2 |
150 |
12 |
400 |
50 |
|
3 |
200 |
12 |
400 |
50 |
|
4 |
300 |
12 |
400 |
50 |
|
5 |
400 |
12 |
400 |
50 |
|
6 |
500 |
12 |
400 |
50 |
|
7 |
100 |
13.2 |
400 |
50 |
|
8 |
150 |
13.2 |
400 |
50 |
|
9 |
200 |
13.2 |
400 |
50 |
|
10 |
300 |
13.2 |
400 |
50 |
|
11 |
400 |
13.2 |
400 |
50 |
|
12 |
500 |
13.2 |
400 |
50 |
When powering heavy industrial generation infrastructure, mitigating harmonic feedback while sustaining high thermal stress is vital.
Complete Grid Protection: The integrated electrostatic copper shield eliminates parasitic capacitance, preventing rectifier harmonics from distorting the main utility line.
Industrial-Grade Endurance: Built with a high capacity safety margin that outperforms nominal rectifier requirements, ensuring stable performance during grid fluctuations.
Maximum Plant Fire Safety: Utilizing advanced vacuum-cast epoxy resin insulation that meets UL V0 standards, the coils are self-extinguishing and will not emit toxic gases.
Precision Thermal Monitoring: Features built-in Pt100 core sensors paired with an intelligent digital thermostat, allowing remote automation tracking from up to 20 meters away.