1. Equipment specifications, model and technical details 2. Available capacity, ratings and dimensions 3. Technical specifications and material composition, as applicable
The SC(B) series is dry-type transformers are characterized by their safety, flame retardancy, fire resistance, and lack of pollution, allowing for direct installation at load centers. They are maintenance-free, easy to install, and offer low overall operating costs. With excellent moisture resistance, they can operate normally in 100% humidity and can be put back into service after a shutdown without the need for pre-drying. These transformers feature low losses, minimal partial discharge, low noise levels, and superior heat dissipation; under forced-air cooling, they can operate at 150% of their rated load. They are also equipped with a comprehensive temperature protection and control system, ensuring reliable and safe operation.
How is noise reduced in dry-type transformers?
Design: Adjust the core proportion coefficients to avoid resonance frequencies.
Materials: Use high-quality silicon steel sheets to minimize magnetostriction.
Manufacturing: Utilize advanced core production lines to ensure processing burrs are ≤0.03 mm.
Assembly: Employ an advanced five-step lamination process to reduce air gaps at the core joints.
What are the 8 factory tests and 2 routine tests for dry-type transformers?
8 factory tests: Voltage ratio measurement, DC resistance measurement, insulation resistance measurement, power-frequency withstand voltage test, induced withstand voltage test, no-load current and no-load loss measurement, load loss measurement, and partial discharge measurement.
2 routine tests: Lightning impulse test and temperature rise test.
Our transformers feature a sophisticated monitoring system to ensure stable operation under all load conditions:
We provide high-quality protection options tailored to your installation environment:
Note: Using an IP23 enclosure may affect cooling capacity by 5% to 10% depending on the unit size.
| Rated capacity | Voltage | Bonding Group Label | No-load loss | Load loss | No-load current | Impedance voltage | ||
|---|---|---|---|---|---|---|---|---|
| High voltage (kV) | High voltage tap range (%) | LV (kV) | ||||||
| 30 | 6 6.3 6.6 10 10.5 11 20 |
± 2 * 2.5 ±5 |
0.4 |
Dyn11 |
190 | 710 | 2.5 | 4.0 |
| 50 | 270 | 1000 | 2.0 | |||||
| 63 | 325 | 1180 | 1.8 | |||||
| 80 | 370 | 1380 | 1.5 | |||||
| 100 | 400 | 1570 | 1.4 | |||||
| 125 | 470 | 1850 | 1.3 | |||||
| 160 | 540 | 2130 | 1.3 | |||||
| 200 | 620 | 2530 | 1.2 | |||||
| 250 | 720 | 2760 | 1.1 | |||||
| 315 | 880 | 3470 | 1.0 | |||||
| 400 | 980 | 3990 | 1.0 | |||||
| 500 | 1160 | 4880 | 0.9 | |||||
| 630 | 1340 | 5880 | 0.9 | |||||
| 630 | 1300 | 5960 | 0.9 | 6.0 | ||||
| 800 | 1520 | 6960 | 0.8 | |||||
| 1000 | 1770 | 8130 | 0.8 | |||||
| 1250 | 2090 | 9690 | 0.7 | |||||
| 1600 | 2450 | 11730 | 0.7 | |||||
| 2000 | 3050 (South Network) 3320 (International) |
14450 | 0.6 | |||||
| 2500 | 3600 (South Network) 4000 (International) |
17170 | 0.6 | |||||
| 1600 | 2450 | 12960 | 0.7 | 8.0 | ||||
| 2000 | 3050 (South Network) 3320 (International) |
15960 | 0.6 | |||||
| 2500 | 3600 (South Network) 4000 (International) |
18890 | 0.6 | |||||
To provide you with an accurate quotation, please provide the following technical specifications when placing an order or inquiry:
| Technical Parameters | Specifications / Options |
| Rated Capacity (kVA) | [Please specify] |
| High Voltage (HV) Rating (kV) | □ 10 □ 35 □ Others: ______ |
| HV Tapping Range (%) | □ ±2 * 2.5 □ Others: ______ |
| Low Voltage (LV) Rating (kV) | □ 0.4 □ Others: ______ |
| Number of Phases | □ Single-phase □ Three-phase |
| Frequency (Hz) | □ 50Hz □ 60Hz |
| Vector Group | □ Yyn0 □ Dyn11 □ Others: ______ |
| Short-circuit Impedance (%) | □ 4% □ 6% □ 8% □ Others: ______ |
| Insulation Class | □ Class F □ Others: ______ |
| Cooling Method | □ AN (Natural Air) □ AN/AF (Air Force) □ Others: ______ |
| Protection Rating (IP) | □ IP00 □ IP20 □ IP23 □ Others: ______ |
| Enclosure Entry/Exit Method |
□ Top In / Top Out (HS1) □ Bottom In / Top Out (HS2) □ Bottom In / Bottom Out (HS3) □ Side Entry/Exit |
| Operational Environment |
□ Altitude ≤ 1000m □ Ambient Temperature: ______ |
| Temperature Control System | [Please specify requirements for installation] |
| Order Quantity | [Please specify] |
| Required Delivery Date | [Please specify] |
| Additional Requirements | [Please specify any other customized requests] |
Every transformer manufactured at our facility undergoes a series of rigorous routine tests to ensure full compliance with international standards and guaranteed performance before dispatch:
Voltage Ratio Measurement & Vector Group Verification: Ensures the transformation ratio and phase relationship meet design specifications.
Winding Resistance Measurement: Checks the integrity of the conductive path and connections.
Insulation Resistance Test: Verifies the dielectric strength and quality of the insulation system.
Separate-Source Voltage Withstand Test (Applied Voltage Test): Tests the insulation between windings and to the earth.
Induced Overvoltage Withstand Test: Validates the turn-to-turn and layer-to-layer insulation integrity.
No-load Loss & No-load Current Measurement: Evaluates core performance and energy efficiency at zero load.
Short-circuit Impedance & Load Loss Measurement: Assesses efficiency and performance under rated load conditions.
Partial Discharge (PD) Measurement: A critical test for dry-type transformers to ensure long-term insulation reliability and detect any internal defects.